Airtight Sun Control Specifications.
We deliver technical precision for Architects and QSs, ensuring SANS 10400-XA compliance and preventing low-quality tender substitutions.
YEARS EXPERTISE
SANS APPROVAL
SOMFY EXPERTS
Tender Specification Consulting Packages
Click any module card to view details. Choose individual modules or save 10% with the complete bundle.
Building Facade Analysis
Comprehensive assessment of building facades for optimal blind and shading system integration. Covers orientation analysis, glazing ratios, structural framing, and sun exposure mapping to determine ideal shading strategies for each elevation.
- Identify key facade parameters that influence shading system selection including orientation, glazing ratio, and structural composition Analyse solar exposure patterns across all building elevations using industry-standard assessment tools Apply facade assessment data to develop evidence-based shading strategies Evaluate existing facade conditions to determine retrofit shading feasibility Design integrated shading solutions that complement the architectural intent of each facade
Shading Strategy Development
Expert selection and specification of roller blinds, venetians, verticals, and external sun control products matched to each window type, performance requirement, and interior design brief.
- Identify the primary performance drivers for shading selection across different building typologies Analyse the interaction between shading systems, natural daylight, and artificial lighting Apply a structured decision framework to select appropriate shading products for each application Evaluate trade-offs between energy performance, visual comfort, and cost Design a comprehensive shading strategy document suitable for client presentation
Motorisation Selection & Specification
Complete motorisation design including motor selection, power supply calculations, wiring schematics, control interface specification, and integration with building management systems.
- Identify appropriate motor types and specifications for different blind systems and window sizes Calculate power requirements and specify electrical infrastructure for motorised installations Apply wiring standards and protocols for Somfy, KNX, and DALI integration Evaluate automation control strategies including solar sensors, timers, and scene management Specify complete motorisation packages with all required components and accessories
IBMS Integration Planning
Detailed specification for integrating blind and sun control systems with Integrated Building Management Systems including protocol selection, point schedules, and commissioning requirements.
- Identify appropriate communication protocols for shading system integration with IBMS platforms Analyse building automation requirements to determine integration scope and complexity Apply point schedule methodologies to define all required data exchange between systems Evaluate integration approaches for existing versus new-build BMS installations Design integration specifications that enable coordinated building system performance
Bill of Quantities Preparation
Detailed BOQ preparation with line items for every blind, motor, control device, bracket, and accessory — priced and quantified from architectural drawings for accurate tender pricing.
- Identify all quantifiable components in a shading installation from architectural and shop drawings Calculate accurate quantities using industry-standard measurement conventions Apply BOQ formatting standards appropriate for South African tender processes Evaluate tender submissions against BOQ specifications to identify pricing anomalies Prepare complete BOQ documentation suitable for NBS-aligned specification systems
Tender Document Compilation
Professional tender document compilation covering technical specifications, scope of work, performance criteria, installation methodologies, and compliance requirements formatted for tender issue to contractors.
- Identify the essential components of a comprehensive shading tender document Analyse specification clauses to ensure they are enforceable and unambiguous Apply NBS-aligned formatting and referencing conventions Evaluate tender responses against specification requirements Compile complete tender packages ready for issue to main contractors
Installation Specification Writing
Detailed installation methodology specifications covering fixing requirements, sequence of works, quality checkpoints, and site coordination requirements for shading system installations.
- Identify critical installation parameters that must be specified for each shading system type Analyse substrate conditions to specify appropriate fixing methods and load capacities Apply installation sequence planning to minimise on-site conflicts with other trades Evaluate installation quality using defined checkpoint criteria Specify complete installation methodologies suitable for inclusion in tender documentation
Commissioning Procedures
Systematic commissioning procedures for motorised and automated shading systems including functional testing, scene programming, sensor calibration, and handover documentation.
- Identify all commissioning requirements for manual, motorised, and automated shading systems Apply systematic testing procedures to verify system performance against specification Evaluate commissioning results and determine acceptance criteria Design commissioning documentation that provides a complete record of system setup Specify commissioning requirements in tender documentation to ensure contractor accountability
Maintenance Schedule Planning
Comprehensive maintenance schedule development covering preventive maintenance intervals, component replacement planning, warranty management, and lifecycle cost analysis for shading installations.
- Identify maintenance requirements for different shading system types and components Calculate lifecycle costs including maintenance, repair, and replacement intervals Apply preventive maintenance scheduling methodologies appropriate to shading systems Evaluate warranty terms and incorporate warranty management into maintenance plans Design comprehensive maintenance manuals for facilities management teams
Project Management for Shading
Project management methodologies tailored to shading installations covering procurement timelines, contractor coordination, progress monitoring, and variation management for sun control projects.
- Identify the unique project management challenges associated with shading installations Apply procurement planning methodologies to manage lead times for imported shading products Evaluate contractor progress against project milestones and specification requirements Design project schedules that account for dependencies with other building trades Specify variation management procedures that protect the original design intent
Post-Occupancy Evaluation
Structured post-occupancy evaluation methodology for assessing shading system performance, occupant satisfaction, energy impact, and maintenance effectiveness after building handover.
- Identify key performance indicators for post-occupancy evaluation of shading systems Analyse occupant feedback data to assess shading system effectiveness Apply energy monitoring techniques to quantify the impact of shading on building performance Evaluate maintenance records to identify system reliability issues Design post-occupancy evaluation reports that inform future specification improvements
Client Handover Documentation
Complete client handover package preparation including operation manuals, warranty certificates, as-built drawings, maintenance schedules, and emergency contact procedures for shading installations.
- Identify all documentation components required for a complete shading system handover Apply documentation standards to ensure consistency and professionalism Evaluate as-built conditions against original specifications to document any variations Design operation and maintenance manuals tailored to the building's specific installations Specify handover requirements in tender documentation to ensure contractor compliance